Hypo Piping in Electrolyzer Installation

April 20, 2019 at 10:36 AMadmin
Scales being settled on the hypo tank and pipeline and which had blocked the pipeline over the period of operation., [More]

Posted in: Case Study

Tags: , , ,

SEAWATER STRAINER in Electrolyzer Installation

April 20, 2019 at 10:20 AMadmin
Particles has retained inside the filter element create a layer of debris resulting increases the differential pressure. [More]

Posted in: Case Study

Tags:

MEASURES FOR THE ACID CLEANING EFFICIENCY:

April 18, 2019 at 10:41 AMadmin
During acid washing, the operator should determine the concentration of the circulating spent acid once in every 30 minutes by chemical titrimetric analysis and make sure concentration remains 5~6% HCL (w/w) if not, maintain the concentration by adding concentrated acid. [More]

Posted in: Electrochlorinator | General | Titanium Electrolyzer

Tags: , , , , ,

Earthing Electrode (GENERAL)

April 16, 2019 at 10:14 AMadmin
Purpose of earthing electrode is to protect the instrument and equipment's from surge current. [More]

Posted in: Electrochlorinator | General | Titanium Electrolyzer

Tags: , , , , ,

ELECTROLYZERS ACID CLEANING (GENERAL)

April 15, 2019 at 10:07 AMadmin
It is well known that the generators of active chlorine by electrolysis of seawater are fouled by precipitation on the cathodes of hydroxides and carbonates cations, such as magnesium and calcium, present in the feed solution. [More]

Posted in: Electrochlorinator | General | Titanium Electrolyzer

Tags: , , , , ,